Lucene search

K

APC UPS Network Management Card 2 AOS Security Vulnerabilities

cve
cve

CVE-2021-22811

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply...

6.1CVSS

6.2AI Score

0.001EPSS

2022-01-28 08:15 PM
30
cve
cve

CVE-2021-22814

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including...

6.1CVSS

6.2AI Score

0.001EPSS

2022-01-28 08:15 PM
30
cve
cve

CVE-2021-22815

A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J,....

5.3CVSS

5.2AI Score

0.001EPSS

2022-01-28 08:15 PM
28
cve
cve

CVE-2021-22813

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products:.....

6.1CVSS

6.1AI Score

0.001EPSS

2022-01-28 08:15 PM
29
cve
cve

CVE-2021-22812

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power...

6.1CVSS

6.2AI Score

0.001EPSS

2022-01-28 08:15 PM
37
cve
cve

CVE-2021-22810

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products:....

6.1CVSS

6.1AI Score

0.001EPSS

2022-01-28 08:15 PM
37
cve
cve

CVE-2018-7820

A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then...

9.8CVSS

9.3AI Score

0.002EPSS

2019-09-17 08:15 PM
74